Surgical Tech Sterile Processing Final Exam Study Guide with Correct Answers
Typology: Exams
1 / 19
This page cannot be seen from the preview
Don't miss anything!
Recommended practices are: Statements of sound principles of practice that are based on scientific data and the opinions of experts. Standards for sterile processing are developed by the: Association for the Advancement of Medical Instrumentation.
Transport in sterile water
a patient contracts an infection from an improperly sterilized surgical instrument. this is an example of a nosocomial infection coronary artery bypass surgery may be performed on patients with arteriosclerosis all of the following are classified as critical medical devices except: thermometers the function of the gastrointestinal system is to provide the body with nutrients a liver biopsy would be performed to check for which disease hepatitis c virus the growth of pathogenic bacteria in living tissue is called sepsis nosocomial infections can be prevented by all of the following except: increasing the patient length of stay
healthcare workers are most likely to be infected by which of the following agents hepatitis B a staff member brings several contaminated trays to the SPD on a cart and requests that replacement trays be put on the same cart. the technician should clean and dry the transport cart and send it to distribution for the trays all of the following items of personal protective equipment (PPE) should be worn when manually decontaminating flexible fiber optic endoscopes except: a lead apron which of the following BEST describes the manual cleaning process of surgical instruments cleaning/brushing the instrument beneath the water level A technician working in Decontamination notices that the maintenance person working on the washer/sterilizer did not remove the barrier attire when the person left the area to get additional tools. The technician should ask the maintenance person to remove the barrier attire when leaving the area while delivering sterile supplies to multiple nursing units, the SPD technician is asked by a unit secretary to take an opened and used tray of instruments back to the SPD decontamination area. which of the following is the BEST procedure to use return for the used tray after completing all deliveries, using the appropriate collection cart when preparing the instruments from a dissection set for processing in a washer/decontaminator, the instruments should be positioned with the retractors on the bottom of the basket and the hand held instruments on the top
a tray of instruments has been brought to the decontamination area in a saline solution. Which of the following actions should the technician take rinse them with water then clean them in the usual manner an acceptable method of decontaminating an item that has been used on on a patient is to clean with a detergent solution and then use an appropriate disinfection agent When working the decontamination area, transmission of pathogenic organisms from used surgical instruments can BEST be minimized by wearing appropriate personal protective equipment plastic sterilization bags are generally used to package respiratory therapy items when using the sequential wrapping method... apply one wrapper followed by a second one surgical grade instruments, if properly cared for, will last longer than floor grade instruments bc they have a ... passivation layer if the operating room requests instruments for an emergency ruptured aortic aneurysm, the technician should send major vascular instruments
which of the following is the main DISADVANTAGE of using a rigid sterilization container system they must be disassembled, processed, reassembled, and checked before each use containerized packaging systems are most commonly used to protect which of the following during steam sterilization surgical instrument sets simultaneous wrapping means to wrap an instrument set with a single non woven wrapper, double ply, bonded at the edges clamps used for hemostasis are also designed to minimize damage to tissue an instrument tray for a laparotomy procedure must include an abdominal retractor inspection and verification of adequate cleaning is difficult with instruments with... with lumens cotton gauze cannot be used in which sterilization process? low temperature gas plasma
which of the following would be the appropriate sterilization cycle for an autoclave load containing a basin set, a minor surgery set, and twelve towel packs 270 F (132 C) for 4 minutes, 30 psi, and 30 minutes drying time drains in pre-vacuum and gravity displacement sterilizers are placed at the bottom front of the sterilizers because.. because the air tends to concentrate at the bottom of the chamber to kill the remaining microorganisms on metal surgical instruments within SPD, the most cost effective sterilization method is generally considered to be.... steam under pressure when heat is added to steam without increasing moisture content, the steam is called... superheated steam which of the following sterilization methods would be appropriate for petrolatum gauze dressings dry heat when a steam sterilizer load contains a mixture of fabric and metal items, where should the items be placed? with the metal items below the fabric items when a steam sterilizer is loaded with linen packs only, the packs should be placed on their edges
there are two pressure gauges on a steam sterilizer. these gauges measure the pressure in the jacket and the chamber a bowie-dick test should be performed in which of the following types of sterilizers pre vacuum steam lot control numbers are used to enable recall following sterilization failure all of the following agencies are involved with the regulation and control of ethylene oxide when it is used as a sterilant EXCEPT the centers for disease control and prevention (CDC) in which distribution system are requisitions filled and delivered as they are received demand sterility maintenance cover should be placed on sterile items when when the sterilized items cool to room temperature which of the following statements is the primary reason that items are allowed to cool on a sterilizer cart before being placed in storage condensation and contamination may result if items are moved to cooler areas when they are still warm which of the following BEST describes the general environmental conditions of SPD sterile storage
tell him/her that this is not the right thing to do you are taking a used IV pump from a nursing unit to be reprocessed. the nurse tells you not to take it because there is an emergency admission and the patient will need it. which of the following would be ethically correct call your department to have a clean pump brought to the unit right away We have an expert-written solution to this problem! You are in a hurry to leave for a doctor's appointment and you forget to punch your time card. Which of the following actions should be taken? report this to your supervisor the next day You receive a cell phone text message from your friend while you're assembling instrument sets. Which action is BEST to take? ignore the text until you are on break which of the following would be an action to take if you note that a coworker has hair hanging out of his/her surgical cap whole assembling sets let him/her know the hair is visible