




























































































Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
Community
Ask the community for help and clear up your study doubts
Discover the best universities in your country according to Docsity users
Free resources
Download our free guides on studying techniques, anxiety management strategies, and thesis advice from Docsity tutors
A comprehensive set of 400 questions and answers related to the asbestos supervisor contractor certification exam. It covers various aspects of asbestos identification, handling, and abatement, including the definition of asbestos, health effects, regulated materials, and clearance procedures. Designed to help individuals prepare for the certification exam by providing a wide range of practice questions and correct answers.
Typology: Exams
1 / 401
This page cannot be seen from the preview
Don't miss anything!
Question: The three most common asbestos forms are crocidolite, amosite, and chrysotile. True False - CORRECT ANSWER✔✔True Question: A material that when dry can be crumbled, pulverized or reduced to a powder by hand pressure is: Friable Non-friable - CORRECT ANSWER✔✔Friable Question: Asbestos Containing Materials (ACM) is any material or product which contains more than one percent asbestos.
True False - CORRECT ANSWER✔✔True Question: Regulated Asbestos Containing Materials (RACM) is any friable material that contains asbestos in a centration greater than one percent. True False - CORRECT ANSWER✔✔True Question: RACM is category I and II nonfriable ACM that has become friable True False - CORRECT ANSWER✔✔True Question: RACM is category I and II nonfriable ACM that has has a high probability of becoming or has crumbled, pulverized, ground, sanded, cut,
Asbestosis Lung Cancer All of the above - CORRECT ANSWER✔✔All of the above Question: RACM is resilient floor covering that when properly removed has minor tears or minor breakage, and for all intent and purposes is consider whole. True False - CORRECT ANSWER✔✔False Question: A vinyl floor tile that has an asbestos content of greater than one percent, and is removed intact is considered RACM? True False - CORRECT ANSWER✔✔True
Question: The three types of ACM are: A.) Crocidolite, amosite, and chrysotile B.) Surfacing, TSI and miscellaneous C.) Surfacing, fiberglass and miscellaneous D.) Tile, mastic and sheet rock - CORRECT ANSWER✔✔Surfacing, TSI and miscellaneous Question: Samples must be sent to a NVLAP laboratory for TEM analysis? True False - CORRECT ANSWER✔✔True Question: What is the permissible exposure limit for asbestos full shift personnel sampling? 1 fiber/cc
0.1 fiber/cc 0.01 fiber/cc - CORRECT ANSWER✔✔1 fiber/cc Question: What is the clearance level for asbestos abatement? 1 fiber/cc 0.1 fiber/mm 0.1 fiber/cc 0 .01 fiber/cc - CORRECT ANSWER✔✔0.01 fiber/cc Question: If you are performing clearance sampling for a non-friable asbestos abatement job, how many sample(s) must you collect inside each containment? 1 3 5
Question: TEM clearance samples are required to confirm completion of ACM removal for abatement jobs exceeding what thresholds? 120 sf or 240 lf 64 sf or 60 lf 240 sf or 120 lf 60 sf or 64 lf - CORRECT ANSWER✔✔64 sf or 60 lf Question: TEM clearance can be used in lieu of PCM if desired, but the PCM cannot be used in lieu of TEM if TEM if required? True False - CORRECT ANSWER✔✔True
Question: The company removing the ACM needs to perform personnel asbestos monitoring as required by LDEQ EPA NIOSH OSHA - CORRECT ANSWER✔✔OSHA Question: Chapter 27, ACM in Schools and State Buildings, applies to all local education agencies, the state government, and federal buildings. True False - CORRECT ANSWER✔✔False Question: According to the Chapter 27, ACM in Schools and State Buildings, the following are School Buildings:
A.) Structures used for instruction, including classrooms, laboratories, libraries, research facilities, and administrative facilities B.) School eating facilities and kitchens C.) Gymnasiums or other facilities used for athletic or recreational activities, or for courses in physical education; D.) Dormitories or other living areas of residential schools; E.) Maintenance, storage, administrative, or utility facilities including hallways used in the operation of the facilities described in this definition F.) Any exterior structure, portico or covered exterior hallway or walkway and any exterior portion of a mechanical system used to condition interior space G.) All of the above - CORRECT ANSWER✔✔All of the above Question: According to the Chapter 27, a state building is a building, or portion thereof, owned, used, or leased by the state of Louisiana. True False - CORRECT ANSWER✔✔True
Question: Category I Nonfriable ACM is asbestos-containing packings, gaskets, resilient floor covering, and asphalt roofing products containing more than 1 percent asbestos. True False - CORRECT ANSWER✔✔True Question: Category II Nonfriable ACM is any material, excluding category I nonfriable ACM, containing more than 1 percent asbestos. True False - CORRECT ANSWER✔✔True Question: Regulated Asbestos-Containing Material (RACM) is friable asbestos material.
True False - CORRECT ANSWER✔✔True Question: Regulated Asbestos-Containing Material (RACM) is category I and II nonfriable ACM that has become friable such as asbestos-cement material that is not removed from a facility prior to demolition. True False - CORRECT ANSWER✔✔True Question: Regulated Asbestos-Containing Material (RACM) is category I and II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, ground, sanded, cut, abraded, or reduced to powder by the forces that have acted or are expected to act on the material in the course of demolition or renovation operations. True
True False - CORRECT ANSWER✔✔True Question: According to Section 5151, no demolition or renovation activity that disturbs RACM or ACDA shall be conducted at a facility regulated by section 5151, subsection h unless at least one _____________ is present. A.) Accredited Asbestos Inspector B.) Accredited Asbestos Project Designer C.) Accredited Asbestos Contract Supervisor D.) Accredited Asbestos Management Planner - CORRECT ANSWER✔✔Accredited Asbestos Contract Supervisor Question: According to Section 5151, all asbestos abatement workers who are performing demolition or renovation activity that disturb RACM or ACDA do not need to be Accredited Asbestos Workers.
True False - CORRECT ANSWER✔✔False Question: According to Section 5151, an Accredited Asbestos Project Designer needs to design all projects disturbing RACM or ACDA. True False - CORRECT ANSWER✔✔False Question: According to Section 5151 and OSHA 1926.1101(k)(8), the employer shall ensure that labels of bags or containers of protective clothing and equipment, scrap, waste, and debris containing asbestos fibers bear the following information: DANGER CONTAINS ASBESTOS FIBERS MAY CAUSE CANCER
Question: Conduct clearance sampling only after an Asbestos Contractor Supervisor has visually inspected the work area. True False - CORRECT ANSWER✔✔True Question: According to EPA Part 763, Subpart E, Appendix A, the Asbestos Contractor Supervisor will select clearance sampling sites in the abatement area on a ________ basis to provide unbiased and representative samples. A.) Selective B.) Approved C.) Random D.) All of the above can recommended - CORRECT ANSWER✔✔Random Question: According to EPA Part 763, Subpart E, Appendix A, page 798, air filtration units (negative air machines) will remain on during clearance testing.
True False - CORRECT ANSWER✔✔True Question: According to EPA Part 763, Subpart E, Appendix A, the _____________ of an abatement area will be swept with a one horse power leaf blower during the aggressive sampling. A.) Just the walls B.) Walls, floors, & ceiling C.) Just the floors D.) None of the above - CORRECT ANSWER✔✔Walls, floors, & ceiling Question: According to EPA Part 763, Subpart E, Appendix A, stationary fans will be placed in the containment area(s) and face towards the __________ after aggressive sampling and throughout clearance testing. A.) Floor B.) The direction does not matter